Loading...
Edwards Conditional Use Permit reportCITY OF SHOREWOOD 5755 COUNTRY CLUB ROACH - SHORRWOOD, MINNESOTA 55331 -8927 - (952) 474 -32361 FAX (952) 474 -0128 ® www.d.shorewood.rnn.us - dtyhall @ci.shorewood.mn.us TO: Planning Commission, Mayor and City Council FRONT: Brad Nielsen DATE: 31 March 2010 RE: Edwards, Mary — Conditional Use Permit for Construction on a Substandard Shoreland Lot FILE NO.: 405 (10.01) Mary Edwards is the owner of the property at 6170 Ridge Road (see Site Location map — Exhibit A, attached). She proposes to demolish the existing home on the property and build a new one in its place (see Exhibits B -E). Since the lot is substandard in area for the zoning district in which it is located, her contractor, Dan Meuisi, has applied for a conditional use permit pursuant to Section 1201.26 Subd. 5.b. of the City Code. The subject property is located on Christmas Lake and is zoned R -lA /S, Single - Family Residential /Shoreland. The lot contains only 28,730 square feet of area, where the R -1A District requires a minimum of 40,000 square feet, making it nonconforming. The topography of the site rises from the shoreline of Christmas Lake approximately 54 feet to where the existing house sits, then another eight feet to Ridge Road. As shown on Exhibits B and C, the property is also occupied by two accessory structures, a small, two -car garage, located only ten feet from the edge of the street pavement, and a shed and deck structure located approximately 14 feet from the shoreline of Christmas Lake. Both of these structures are grossly nonconforming in terms of required setbacks. An existing stairway and an elevated lift system provide access down to the lake. The existing house contains approximately 1411 square feet on the main level according to the applicant's survey. Although no plans were submitted for the existing structure, it appears that there may be an additional 1400 square feet of floor area in a lower, walk -out level, plus some additional square footage in an upper dormer level. The existing garage contains 418 square feet 41% # PRINTED ON RECYCLED PAPER Memorandum Re: Edwards C,U.E, 31 March 2010 and the shed near the lake contains 111 square feet of floor area with an approximately 198 square -foot deck. t A. Nonconforming Accessory Structures. As mentioned above, both the shed near the lake and the garage near the road are very nonconforming with respect to R -IA /S zoning requirements. For example, the garage is required to be set back from the (private) road 65 feet. It is only 10.3 feet from the edge of the Ridge Road pavement. Furthermore, it is less than three feet from the south property line, where 20 feet minimum is required. If left in place, the existing garage would create an additional nonconformity — two driveways without adequate lot width. The Zoning Code only allows one driveway per 120 feet of lot width. The shed and deck near the lake are approximately 14 feet from the water's edge, where 75 feet is required. Also, the shed is only 8.7 feet from the south lot line where 20 feet is required. Several sections of the Zoning Code dictate that the nonconforming accessory structures on the property be removed, or at least be moved into conformity with current zoning requirements. First, they are only allowed as accessories to the principal structure. Once the house is demolished, the accessory structures must also be removed. The City has in the past allowed conforming accessory structures to remain on the property provided construction of a new home commenced within six months of the demolition of the old. Section 1201.03 Subd. 2.d.(5) requires a conditional use permit for the construction of more than one garage on a property. Section 1201.03 Subd. 2.d.(4)(e) requires that any nonconforming accessory structures be removed or brought into conformity with the Zoning Code. B. Substandard Lots. Section 1201.03 Subd. 2.c.(3) of the Zoning Code addresses development on substandard lots of record. Section 1201.26 Subd. 5.b. (Shoreland regulations) goes on to require a conditional use permit for substandard lots in the Shoreland District. Following is how the applicant's request complies with the criteria provided in those sections: 1. The subject property is in separate ownership from the two adjoining lots. 2. The Code requires a substandard lot to have at least 70 percent of the minimum width and area requirements of the zoning district in order to be considered buildable. In this case the lot meets 96 percent of the width requirement (120 feet) and 72 percent of the area requirement (40,000 square feet). -2- Memorand.uni Pie: Edwards C.U.P. 31 March 2010 floor 4. The _ proposed house and garage on t ` percent t lot area, where 30 percent floor area to lot area • is allowed. The provisions of the Shoreland District are the same as 1 -4, above. In addition, the Shoreland provisions require a "shoreland impact plan ". In this case, the applicant should be required to submit an erosion control and restoration plan for the area near the lake where the shed /deck will be removed. With the removal of the two nonconforming accessory structures and the redesign of the building to comply with the front setback requirement, the property will comply better with the Zoning Code than it presently does, despite the lot's substandard area. Subject to the following conditions, approval of the C.U.P. to build on a substandard lot is recommended: A. The applicant should submit an erosion control /restoration plan for the area near the lake where the shed /deck are currently situated. Estimates for the cost of that work should be used as a basis for an escrow agreement to guarantee the work is done within a prescribed time. B. The nonconforming accessory structures should be removed at the same time the existing house is being demolished. If there is some desire to keep the existing garage, a revised site plan should be submitted showing that it will meet setback requirements. C. The building permit plans must include a tree preservation and reforestation plan. Cc: Brian Heck Mary Tietj en Tom Velmer* Mary Edwards *As this report was being finalized, Dan Meuisi informed us that Tom Vebner would be handling the application process. -3- I CD CD L.L N on 3 P FA • 10 all 0 IE 0 ca 6 OS cu ca CL 0 CO CL IE 0 ca 6 OS cu ca CERTIFICATE OF SURVEY FOR CORNERSTONE CONSTRUCTION IN GOVT LOT 7, SEC. 36- 117 -23 I- IENNEPIN COUNTY, MINNESOTA I it 461� 0 20 40 80 SCALE IN FEET PROPOSED ELEVATIONS (VERIFY GARAGE WITH BUILDER) 1) =9%5 21 FIRST FLOOR -9975 3) BASEh1ENT -9811 PROPOSED HARDCOVER CALCULATIONS EXISTING LOT = 28730 + - S.F. PROPOSED HOUSE = 2623+ - PROPOSED DRIVEWAY = 1656, PROPOSED PORCH 8 DECK = 492+ - PROPOSED FRONT WALK - 219+ - EXISTING STEPS = 200+ - EXISTING SHED DECK = 208. - EXISTING SHED = 110+ - EXISTINGGARAGE - EXISTING GARAGE DRIVEWAY - 418+ - I59+- TOTAL = 5983+ -S.F. 5983 X100= 20.82% PROPOSED HARDCOVER 28730 NOTE: TRAVELLED ROADWAY NOT INCLUDED GROW IN HARDCOVER,,rrJJ`` io` -05s CIVIL ^S 445 N PHO l y �y ^S G 1 3z 00 W O SHED g o � Wm " N � �kn�t�i'lii d /lI ) 7�¢ It =2 7 A =00 21 45 16" L =2.79 PROPOSED `HOUSE <� Y61 70 i is i a % o IS s p N S EXISTING HOUSE �\ o tbz3o P m 9 , w 66'7 -_ -� -- ---- --------------- - � -c -- - - --- K GROW io` -05s CIVIL 7,, 7,, + 7� Exhibit ll 445 N PHO l SITE SURVEY - VICINITY c, e� s rh ti� EXISTING HOUSE #6140 •m S .- 11 ,00 91.V1 N ED O! Tk CD C4 LLI till? 966 nnz NO T 3 rrl CY i L .......... oop� _06J -- ------- - CO I 7sawn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5: 096- k6 '01. 27 IV Alm 7 % ­z; V, L 0 SHNKI W 'CIO OAA ] R 0 H S VLI :13KH(IIS H SaHVAk(l it 0 Lu < co :HHl'U0AHW0H AkHM D -� 5 : (5 - uj uj mm 37 In — — — — — -- — — — — MGR In 7, w L5 12 O HDN.99 ;lEQ W4 ff �IN�o 02M�V,f w v 391 X ILL d) z ILI qa Zo too r I c U, <[ LL 0=0 j) XU O F�q w I K 0 w a j) ILL w X X w w .0-M Exhibit D PROPOSED FIRST FLOOR PLAN V—TOSqNM !&I'CIOOM S U) L I 33Naalsau SCIHVM(I:l u I i m LD 'UHI WOA qWOH Ak R I uj F 373 N 1-4 (t I : 1 4 M z <1 W -1 W O LL HA -A W W (Y- Exhibit E PROPOSED BUILDING ELEVATIONS