Bridge Inspection Report 20172017 ROUTINE
BRIDGE INSPECTION REPORT
BRIDGE # 27A34
81 (ENCHANTED LANE) over CHANNEL
DISTRICT: Metro
STATE: Minnesota
Date of Inspection:
Equipment Used:
COUNTY: Hennepin
08/29/2017
Owner: City or Municipal Highway Agency
Inspected By: Flittie, Daniel
Report Written By: Daniel Flittie
Report Reviewed By: Craig Alberg
Final Report Date: 09/06/2017
CITY /TOWNSHIP: Shorewood
Table of Contents
SECTION
COVER
STRUCTUREINVENTORY
ELEMENTS
PICTURES
PICTURES - THUMBNAILS
BRIDGE 27A34 RATING (2011)
DRAWINGS
PAGE
1
2
3
6
18
19
22
Minnesota Structure Inventory Report
Bridge ID: 27A34 81(ENCHANTED over CHANNEL
LANE)
Date: 08/29/2017
+GENERAL+
+ROADWAY+
+INSPECTION+
Agency Br. No. Crew
Bridge Match ID (TIS) 0
Userkey 194
District 05 Maint. Area
Roadway O/U Key Route On Structure
Structurally Deficient N
County 027 - Hennepin
Route Sys 10 -MUN Number 81
Functionally Obsolete N
City Shorewood
Roadway Name or Description
Sufficiency Rating 74.6
Township
MUN 81
Routine Inspection Date 08/29/2017
Desc. Loc. TO SHADY ISLAND
Level of Service 1 -MAINLINE
Routine Inspection Frequency 24
Sect., Twp., Range 30 - 117N - 23W
Roadway Type 2 - 2 -way traffic
Inspector Name Flittie, Daniel
Latitude 44 ° 54, 43.18 ,,
Control Section (TH Only)
Status A - Open
Longitude -93 ° 38, 10.87 ,,
Reference Point
+ N B I CONDITION RATINGS +
Custodian 04 - City or Municipal Highway
Detour Length 99.0 mi.
Owner 04 - City or Municipal Highway
BMU Agreement
Lanes ON 2 UNDER 0
ADT 260 YEAR 1988
Deck 8 Unsound
Superstructure 8 Deck
Year Built 1997
HCADT ADTT %
Substructure 8
MN Year Reconstructed
Functional Class 19 - Urban - Local
Channel 8
FHWA Year Reconstructed
Culvert N
MN Temporary Status
+RDWY DIMENSIONS+
+N BI APPRAISAL RATINGS+
Bridge Plan Location 1-CENTRAL
Date Opened to Traffic
If Divided NB -EB SB -WB
Structure Evaluation 8
On -Off System 0-OFF
Roadway Width 20.00 ft. ft.
Deck Geometry 4
Legislative District 33B
Vertical Clearance ft. ft.
Underclearances N
Potential ABC 2 - N/A
Max. Vert. Clear. ft. ft.
Waterway Adequacy 9
Horizontal Clear. ft. ft.
Lateral Clearance ft. ft.
Approach Alignment 8
+STRUCTURE +
+SAFETY FEATURES+
Service On 1 -Highway
Appr. Surface Width 20.0 ft.
Service Under 5 - Waterway
Bridge Roadway Width 20.0 ft.
Bridge Railing 1 -MEETS STANDARDS
Main Span Type 7 - Timber
Median Width On Bridge ft.
GR Transition 0 - SUBSTANDARD
Main Span Design 09 - Slab Span
Appr. Guardrail 1 -MEETS STANDARDS
+MISC. BRIDGE DATA+
Main Span Detail
GR Termini 0-SUBSTANDARD
Structure Flared 0 - No flare
Appr. Span Type
+ I N DEPTH I N S P. +
Appr. Span Design
Parallel Structure N - No parallel structure
Appr. Span Detail
Field Conn. ID
YIN Freq Date
Skew 0
Abutment 2 - TIMBER
Frac. Critical
Culvert Type
Foundation
(Material /Type) 4 - PILE BENT
Underwater 60 09/07/2016
Barrel Length
Pinned Asbly.
Pier Foundation 2 - TIMBER
Cantilever ID
(Material /Type) 4 -PILE BENT
Spec. Feat.
+WATERWAY+
Number of Spans
Historic Status 5 - Not eligible
MAIN: 3 APPR: 0 TOTAL:
Drainage Area (sq. mi.)
Main Span Length 20.0 ft.
+PAINT+
Waterway Opening (sf.) 200
Structure Length 52.0 ft.
Navigation Control 0 - No nay. control on
Deck Width (Out -to -Out) 24.0 ft.
Year Painted
Pier Protection
Deck Material 8 - Wood or Timber
Unsound Paint %
Nay. CIr. (ft.) Vert. 0.0 Horiz. 0.0
Wear Surf Type 6 - Bituminous
Painted Area sq. ft.
Nay. Vert. Lift Bridge Clear. (ft.)
Wear Surf Install Year
Primer Type
MN Scour Code I - LOW RISK Year 2001
Wear Course /Fill Depth 0.29 ft.
Finish Type
+CAPACITY RATINGS +
Deck Membrane 0 - None
Deck Rebars N - Not Applicable (no deck)
Design Load 9 - HS 25 (OR GREATER)
+BRIDGE SIGNS +
Deck Rebars Install Year
Operating Rating 2 - HS TRUCK 36.6
Structure Area (Out -to -Out) 1248 sq. ft.
Posted Load 0 - Not Required
Inventory Rating 2 - HS TRUCK 26.5
Roadway Area (Curb -to -Curb) 1044 sq. ft.
Traffic 0 - Not Required
Posting VEH: SEMI: DBL:
Sidewalk Width 50A. Lt 0.00 ft. 50B. Rt 0.00 ft.
Horizontal 1 - Object Markers
Rating Date 07/26/2011
Curb Height Lt 0.00 ft. Rt 0.00 ft.
Vertical N - Not Applicable
Overweight Permit Codes
Rail Type Lt 06 Rt 06
A N - N/A B N - N/A C N - N/A
MINNESOTA BRIDGE INSPECTION REPORT
09/06/2017
BRIDGE 27A34 81 (ENCHANTED LANE) OVER CHANNEL
County: Hennepin Location: TO SHADY ISLAND
City: Shorewood Route: 10 - MUN 81 Ref. Pt
Township: Control Section:
Section: 30 Township: 117N Range: 23W Maint. Area:
Span Type: 7 - Wood or Timber 1 - Slab Local Agency Bridge Nbr.:
List:
Length: 52.0 ft.
000 +00.000 Deck Width: 24.0 ft.
Rdwy. Area/ Pct. Unsnd: 1044 sq. ft. / %
Paint Area/ Pct. Unsnd: sq. ft. / %
Culvert: N/A
Postings:
NBI Deck: 8 Super: 8 Sub: 8 Chan: 8 Culv: N
Open, Posted, Closed: A - Open
MN Scour Code: I - LOW RISK
Appraisal Ratings - Approach: 8 Waterway: 9
Required Bridge Signs - Load Posting: 0 - Not Required Traffic: 0 - Not Required
Horizntal: 1 - Object Markers Vertical: N - Not Applicable
ELEM
NBR ELEMENT NAME
54 Timber Slab
QT
REPORT TYPE INSP. DATE QUANTITY CS 1
Unofficial Structurally Deficient N
Unofficial Functionally Obsolete N
Unofficial Sufficiency Rating 74.6
Y QTY QTY QTY
CS 2 CS 3 CS 4
Routine 08/29/2017 1152 SF 1152 0 0 0
Underwater 09/07/2016 1248 SF 1248 0 0 0
Notes: [2016] Migrator assumed CS1.
[08/29/17] OTO width = 22' -2 ". OTO bridge field measures 52' -0 ". Slab Area = 1152 sf. Bottom of slab very clean, all spans, no indications of
distress. 4x10 approach span, 4x12 main span.
510 - Wearing Surfaces Routine 08/29/2017 1053 SF 1049 4 0 0
Underwater 09/07/2016 1044 SF 1044 0 0 0
Notes: [08/20/15] Roadway field measures 20' -3" + (2) 11" rub rails, OTO width = 22'-l". OTO bridge field measures 52' -0 ". Slab Area = 1148
sf.
[08/29/17] Recent bituminous /gravel wear course placed across approach road and bridge - no significant depth change; good condition.
[08/29/17] Roadway field measures 20' -3 ", OTO bridge 52' -0 ". Rdwy Area = 1053 sf. Typical full width transverse cracks in wear course over
piers. Say (2 piers) * (20.25') * (1"/12 crack width) => say 4 SF at CS -2, balance at CS -1.
4d6 Timhor Fln r Roam RAutmnp nROQ0017 g ,4 9 9 9 9
216 Timber Abutment Routine 08/29/2017 92 LF 92 0 0 0
Underwater 09/07/2016 102 LF 102 0 0 0
Notes: [2016] Migrator added 40 LF to abutment quantity to account for wingwalls (CS1:40 CS2:0 CS3:0 CS4:0).
[08/20/15] Slight quantity change for field measured dimensions, no condition state change.
Wingwall notes:
[08/20/15] No change.
[08/29/17] Field measure 2' OH (N) + (2) 8' WW + 6' OH (S) + 22' OTO = 46 LF * 2 = 92 LF; all CS -1
228 Timber Pile Routine 08/29/2017 36 EA 36 0 0 0
Underwater 09/07/2016 36 EA 36 0 0 0
Notes: [08/20/15] Remove timber column quantity, coded incorrectly. 10 piles at each abutment/ww + 8 piles at each pier, total = 36, all in
Condition State 1.
[08/29/17] Steel shims under the timber cap of a few piles; all piles in contact with cap or shims; no CS change.
235 Timber Pier Cap Routine 08/29/2017 120 LF 120 0 0 0
Underwater 09/07/2016 124 LF 124 0 0 0
Notes: [08/20/15] Slight quantity change for field measured dimensions, no condition state change.
[08/29/17] 4 @ 30' -2" = 120 LF; all CS -1. Minor weathering on the exposed overhangs.
BRIDGE 27A34 81 (ENCHANTED LANE) OVER CHANNEL
ELEM
QTY
QTY
QTY
QTY
NBR
ELEMENT NAME REPORT TYPE INSP. DATE QUANTITY CS 1
CS 2
CS 3
CS 4
332
Timber Bridge Railing Routine 08/29/2017 104 LF 104
0
0
0
Underwater 09/07/2016 104 LF 104
0
0
0
Notes: [08/20/15] No change.
[08/29/17] No change.
800
Critical Deficiencies or Safety Hazards Routine 08/29/2017 1 EA 1
0
0
0
Underwater 09/07/2016 1 EA 1
0
0
0
Notes: NO CRITICAL FINDINGS OBSERVED DURING THE LAST INSPECTION.
[08/20/15] No change.
[08/29/17] No change.
822
Bituminous Approach Roadway Routine 08/29/2017 2 EA 2
0
0
0
Underwater 09/07/2016 2 EA 2
0
0
0
Notes: [08/20/15] No change.
[08/29/17] Recent bituminous /gravel wear course placed across approach road; good condition.
855
Secondary Members (Superstructure) Routine 08/29/2017 1 EA 1
0
0
0
Notes: [08/29/17] Member added for spreader beams. Deleted Floorbeam (Item 156). Member is secondary, acts as a diaphragm, not a
primary member which a floor beam is, disagree with BSIPM B.3.3.4. Notes below from previous inspection.
Item
is a "1" qty,
all spreader
beams in good condition, CS -1.
------------------------
[08/20/15] Element added. 12x6 timber section; (1) stiffener beam in each approach span & (2) stiffener
beams in
the main
span. Same
quantity as timber cap, 124 LF, all in Condition State 1
885
Scour Routine 08/29/2017 1 EA 1
0
0
0
Underwater 09/07/2016 1 EA 1
0
0
0
Notes: [08/29/17] No scour evident, channel armor in place. Underwater inspection performed 09/07/16.
891
Other Bridge Signing Routine 08/29/2017 1 EA 0
0
1
0
Underwater 09/07/2016 1 EA 1
0
0
0
Notes: [08/20/15] Element added. All object markers accounted for and visible. Vegetation growth at SW corner of abutment growing up
around object marker.
[08/29/17] Heavy vegetation at SW and SE corners, beginning to obscure signs.
[08/29/17] Gas marker on east end of bridge, totally obscured by vegetation; no marker visible on the west end; downgrade
to CS -3 for
vegetation removal around object marker sign.
892
Slopes & Slope Protection Routine 08/29/2017 1 EA 1
0
0
0
Underwater 09/07/2016 1 EA 1
0
0
0
Notes: [08/20/15] No change, channel slopes well protected.
[08/29/17] No change.
893
Guardrail Routine 08/29/2017 1 EA 1
0
0
0
Underwater 09/07/2016 1 EA 1
0
0
0
Notes: [08/20/15] No change.
[08/29/17] No change.
894
Deck & Approach Drainage Routine 08/29/2017 1 EA 1
0
0
0
Underwater 09/07/2016 1 EA 1
0
0
0
Notes: [08/20/15] No change, deck scuppers open, free of debris.
[08/29/17] No change.
895
Sidewalk, Curb, & Median Routine 08/29/2017 1 EA 1
0
0
0
Notes: [08/29/17] Member added for timber curb, part of the timber rail system. Good condition throughout; CS -1.
BRIDGE 27A34 81 (ENCHANTED LANE) OVER CHANNEL
ELEM QTY QTY QTY QTY
NBR ELEMENT NAME REPORT TYPE INSP. DATE QUANTITY CS 1 CS 2 CS 3 CS 4
899 Miscellaneous Items Routine 08/29/2017 1 EA 0 0 1 0
Underwater 09/07/2016 1 EA 1 0 0 0
Notes: [08/20/15] Element added. (3) separate conduits on the south side of the bridge. (1) 3" gas line, marked at east end of bridge; (1) 16"
conduit (insulated water main ?); & (1) 4" conduit (galvanized ?).
[08/29/17] Gas marker on east end of bridge, totally obscured by vegetation; no marker visible on the west end; downgrade to CS -3 for
vegetation removal around this and object marker sign.
900 Protected Species Routine 08/29/2017 1 EA 0 1 0 0
Underwater 09/07/2016 1 EA 1 0 0 0
Notes: Use this element to track the presence of protected species living on this structure.
[08/29/17] Swallow nests on bridge, CS -2.
General Notes: [08/20/15] Inspection by WSB.
[08/20/15] 40" clearance to bottom of spreader beam in Span 2.
[08/20/15] 4' water depth in channel under Span 2.
[08/20/15] Removed element 206.
[08/20/15] Added element 228.
[08/20/15] Added element 415.
[08/20/15] Added element 981.
[08/20/15] Vegetation growing at SW corner of bridge, nearly obstructing object markers, should be removed.
[08/29/17] Inspection by WSB & Associates. Vegetation growing at SW & SE corner of bridge, nearly obstructing object
markers, should be removed.
[08/29/17] 2011 load rating does not include SHV load ratings. See BSIPM A.8.2: "Section 15.6 of the MnDOT LRFD Bridge
Design Manual states that a new bridge load rating should be calculated whenever change occurs that would sufficiently
change the rating. The most commonly encountered types of changes are: A change in the laws regulating truck weights."
Owner should consider load rating bridge with updated SHV truck loads.
58. Deck NBI:
[08/20/15] Timber slab covered by 3.5" bituminous wear course; no change. Measures 2" at the gutter line, 5" at CL bridge.
[08/29/17] Recent bituminous /gravel wear course placed across approach road and bridge - no significant depth change.
36A. Brdg Railings NBI:
[08/20/15] Change to substandard.
[08/29/15] Barrier is standard for — 40 mph.
36B. Transitions NBI:
[08/20/15] No change.
[08/29/15] Change to substandard.
36C. Appr Guardrail NBI:
[08/20/15] No change.
[08/29/15] No change.
36D. Appr Guardrail
[08/20/15] Change to substandard. Approach guardrail ends are turned down.
Terminal NBI:
[08/29/15] No change.
59. Superstructure NBI:
[08/20/15] Timber slab covered by 3.5" bituminous wear course; bottom of timber slab stringers in very good condition in all
spans, no change.
[08/29/17] 4x10 approach span, 4x12 main span.
60. Substructure NBI:
[08/20/15] No change.
[08/29/17] No change.
61. Channel NBI:
[08/20/15] No change. 40" freeboard to Span 2 spreader beam.
[08/29/17] Downgrade to 8, bridge no longer in 'new' condition.
62. Culvert NBI:
[08/20/15] No change.
[08/29/17] No change.
71. Waterway Adeq NBI:
[08/20/15] No change.
[08/29/17] No indications of high -water anywhere near low bridge member.
72. Appr Roadway
[08/20/15] No change.
Alignment NBI:
[08/29/17] No change.
Daniel Flittie
Inspector's Signature
Craig Alberg
Reviewer's Signature
Pictures
Photo 1 - New bituminous /aggregate wearing surface on bridge and approach slab.
�. 4 f a+
Photo 2 - Typical wearing surface cracks over piers.
Pictures
Photo 3 - 3 conduits on south side of bridge.
low,
P"
Photo 4 - Typical timber railing.
Pictures
Photo 5 - West approach.
Photo 6 - East approach.
Pictures
77�--
Photo 7 - South channel.
Photo 8 - North channel.
6E
Pictures
Photo 9 - Western guardrails.
. t, .
iiyll..
MF�w
10
140
Photo 10 - Eastern guardrails.
10
Pictures
Photo 11 - East abutment and channel protection.
Photo 12 - East face, Pier 2.
11
Pictures
t.
Photo 13 - Span 3; timber spreader beam.
Photo 14 - Span 3, bottom of slab.
`V
Pictures
Photo 15 - Gas marker, SE corner of bridge, totally obstructed by vegetation.
Photo 16 - West abutment and channel protection.
13
Pictures
Photo 17 - West face, Pier 1.
Photo 18 - Span 1 spreader beam.
`C!
Pictures
Photo 19 - Span 1, bottom of timber slab.
Photo 20 - Timber pier cap, Pier 2.
15
Pictures
Photo 21 - Bottom of timber slab, Span 2.
[i
Photo 22 - West face, Pier 2.
16
r4til��r
'J ftr
•..i: x c� f t .
I{�Q
Pictures
r.
r
'x
Photo 23 - Span 2 spreader beam.
Photo 24 - Looking NW.
17
1.
170829 27A34 comp_
(001).JPG
6.
170829 27A34_comp_ G
(6).JP
2. 3.
170829 27A34_comp_ 170829 27A34_comp_
(2).JPG (3).JPG
� oh
4.
170829 27A34_comp_
(4).JPG
7.
170829 27A34_comp
(7).JPG
8.
170829 27A34_comp_
(8).JPG
9.
170829 27A34_comp_
(9).JPG
11.
170829 27A34_comp_
(11).JPG
13.
170829 27A34_comp_
(13).JPG
16.
170829 27A34_comp_
(16).JPG
17.
170829 27A34_comp_
(17).JPG
18.
170829 27A34_comp_
(18).JPG
14.
170829 27A34_comp_
(14).JPG
19.
170829 27A34_comp_
(19).JPG
21. 22. 23.
170829 27A34_comp_ 170829 27A34_comp_ 170829 27A34_comp_
(21).JPG (22).JPG (23).JPG
24.
170829 27A34_comp_
(24).JPG
i
S.
170829 27A34_comp_
(5).JPG
I
10.
170829 27A34_comp_
(10).JPG
15.
170829 27A34_comp_
(15).JPG
20.
170829 27A34_comp_
(20).JPG
FORM RC -CL
KA
F Ind DO T BRIDGE RATING AND LOAD POSTING REPORT
Revised Aug. 2010
FOR COUNTY AND LOCAL AGENCIES
Bridge Location and Description
Over ® Bridge No. 27A34
Hwy. No. 81(Enc. Ln.) under❑ Channel
Year Built 1997 Year Remodeled Replaces Br.
Type 709 County Hennepin Ref. Pt. 000+000.00
Description 3 -span, 16' - 20' - 16', 22' -8" out to out, 20' roadwway
Timber slab span, Iii" - 12" - 10" thickness respectively, 4" Bituminous Overlay
Location Enchanted Lane to Shady Island, City of Shorewood, sec 30, twp 117, rge 23W
Data for Basis of Report (Check all that apply.) NBI Condition Ratings
Deck 9
® Bridge Inventory File Superstructure 8
® Previous Bridge Rating and Load Posting Report Substructure 8
® Bridge Plans
® New ❑ Overlay
❑ Repair /Reconstruction
❑ Other Dead Load Modifications
® Bridge Inspected by City of Shorewood ,date 09/14/09
❑ Damaged Component
❑ Deteriorated Component
Types of Analysis:
❑ Manual ❑ Computer* ❑ BARS ® Virtis, V.662 ❑ Other*
Method of Rating (Check appropriate box)
❑ Load Factor (LF)
Design Load HS -25
® Allowable Stress (AS)
❑ Load & Resistance Factor (LRFR)
❑ Load Testing
Design Method ASD
❑ No Rating Computations performed
Summary of Rating and Load Posting Analysis
Load Posting Required ❑
Bridge Rating
Not Required
Inventory Operating
Sign
TONS
R12 -1A ❑
HS ® H5
R12 -5a ❑
RF ❑ 26.5 RF ❑ 36.58
M3
R12 -5 ❑
M3S2
45
M3 -3
R12 -X11 ❑
SMM
I hereby certify that this report was prepared by me or ugder my direct supervision and that I am a duly Licensed Professionai
Engineer under the laws State of nesota.
Signature: Date: 7/26/11
(Typed or Printed) ame: Aar elson License No. 43101
(Typed or Printed) Employed by (Agency /Firm): WSB & Asst ates, Inc.
r3 eeieFed 1 Q 07 1 L
FORM RD -CL
Revised May 2010
Bridge Type 701
Rating Method ASD
Roadway Width 20' -0"
❑ Curved ❑ Tapered
Beam Spacing NA
Live Load Distribution Lane Width
Single 10 Multiple 10
BRIDGE RATING DETAILS
Bridge No. 27A34
Design Load: HS -20
Inventory Rating: HS- 26.5
Operating Rating: HS- 35.58
Rated A] N Checked
Date: 7/26/11
Sheet 2 of 3
BEAM ELEVATION 2
Show span lengths, structure /beam depths.
Truck Factor Location Limit State 1 Notes /Comments
HS 20 Inventory 1.325 Span1 Ultimate Moment Exterior 1ft section, at center of span
HS 20 Operating 1.829 Span1 Ultimate Moment Exterior 1ft section, at center of span
Post, M 3
Post, M 3S2
Post, M 3 -3
Type SU4
Type SU5
Type SU6
Type SU7
1 Choose from: service or ultimate; shear or moment
2 Elevation may be on back or another sheet if it won't fit here.
page-29 of 3
entered 10 -07 -2011 LH
END IiBNTIIEHi £ PIER 1 4 pf�li'IEL 4 PIER t ENO OF OEC[
1 I EAST A WTWNI
I I i i I
i 1 s E I
I 1• ! l A I r
I f Ilt
il
r l I woo'ro• [lip.; I i I i
r' r - - - - - - - - I I 1 I —
II l
4 RgA1}x0.Y - — - - — • I I T a — - I — - �i _ I I I - - - - - -
i l i I
1�1 I I I
f I I I
I I
RAIUDIf
IC IWIDT WO.
GENERAL PLAN
f� =
GENERAL ELEVATION
SHADY ISLAND BRIDGE
TINUR OCCK PAREl. OPTION
FINfSREO ME
RMVAY
cs
�
�
- -« -- '2
\ �
? ? ?, ? ? ? ? ' \
�
�
�
�
� » a�
? ? ?� ? ? ? 0_ \
----------
\ \\ > ?
\ \
\ \
\ \
/
\
see
\
zi
M
N
Y
Z Q
Oz
F W ZZ ~
za a�a cnU7
a.
-
Q
W I
N H 000!]
o
zI-�
Z O m -I W
�zF D =o a az
wo
' QQ
O'J
=L W
o w
Q W �
a
W z r �
�> >U
O
>
Q
W
j
Q
W
c
O
t0
�
\
N
O \
�O
N
1
N
\
W
W
\ 0
O
l
o
O
11,
a�
c
U
cs
o�
U
U o
c)
I
O
c�
- —
- — - - - — - — - — - — - - — - —
c-v
- — - - - ----- ------
- — - —
I
E
v o
o0
c
�
� o
a
o ° °ro
¢
c°
N
o
s
a
s �
M
N