2019 Bridge No. 27A34MnDOT Bridge Rating Contract — Contract No, 1026817 Hennepin County Bridge No. 27A34 Page 1 of 3 f, Load bating Report For Bridge No. 27A34 Hennepin County MUN 81 (Enchanted Lane) over Channel Mn/DOT Contract No. 1026817 Report Prepared By Widseth Smitli Nolting & Associates, Inc. Alexandria 610 Fillmore Street PO Box 1028 Alexandria, MN 56308 -1028 320.762.8149 320.762.0263 Alexandria@wsn.us.com W idseth5mlthNoiting.com I hereby certify that this report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Ket PA,R h r, P. E. 21179 License No. Date Engineering Architecture Surveying Environmental Recommended Rating and Load Posting: (with consideration of Special Hauling Vehicles) Inventory Rating: HS 23.7 Operating Rating: HS 32.6 Recommended Load Posting: None Required Load Rating Notes: • Load capacity ratings shown are based on Virtis (v6.8) rating using Girder Line Analysis • Used timber allowable bending stress fb = 1500 psi • Used 20" tire contact width for LL Dist, Width calculations for analysis of HS Vehicles • Used 15" tire contact width for LL Dist. Width calculations for analysis of Posting Vehicles • LL distribution factors have been manually input into Virtis • Curb, rail and wearing surface dead loads have been distributed uniformly across slab width BridlZe Condition Summary: Bridge No, 27A34 is a 3 -span nail laminated timber slab span bridge supported on timber pile -bent style abutments and piers. The total length of the bridge from back face of abutment to back face of abutment is approximately 52' -0 ". A span layout of 15' -6 "/ 20'- 0 "/15' -6" (between centerlines of substructures) was considered for the load rating calculations. The total width of the bridge slab is 24' -0 ". Timber curbs and scuppers measured at each edge of the bridge constrict the roadway width to 20' -0 ". Plans were not made available for this structure prior to completing the load capacity rating. The timber slab consists of approximately 4" wide timber laminations that run parallel to the centerline of the roadway and span between the bridge substructure units, The individual timbers are nailed together in a specified pattern to create the timber slab which carries traffic across the bridge. The timber slab was measured in the field to be 10" thick for spans 1 & 3 and 12" thick for span 2. There was a 3 1/2" thick average bituminous wearing course present on the bridge slab at the time of the inspection and was considered for the load capacity rating. The top of the timber slab was not visible due to the wearing course atop the bridge, The underside of the timber slab was in very good condition overall. The slab contained minor weathering. The bituminous wearing course contains minor transverse and longitudinal cracks. The timber spreader beams were tight to the underside of the timber slab superstructure, and the standard live load distribution width for this type of structure was used in the load rating calculations. The spreader beams were in good condition with minor horizontal splitting present. The timber railing was in good condition with minor splitting KInDor Bridge Ruing Contract -- Contract No. 1026817 T Hennepin County Bridge No. 27A34 V V IDS1ETH Page 3 of 3 SMITH N®L'TING present. The timber posts contain some moderate sized vertical cracks. The timber pile -bent style abutments each consist of a square timber cap supported atop 8 round timber piles. Each wingwall is supported by an additional pile. Approximately 2 -3' feet of piling was exposed above the in -slope at each abutment. The amount of rip rap protection on the in- slopes was adequate. The timber abutment caps were in very good condition with minor horizontal splitting present. No crushing was found during inspection. The timber piling contain minor vertical splitting. There was minor horizontal splitting found on the timber backing planks, The wingwalls contained minor splitting. Both abutments appeared to be performing as intended. The abutments are adequately supporting the superstructure loads, and there is no need to downgrade the load rating or posting due to the condition of the bridge abutments, The timber pile -bent style piers each consist of a square timber cap supported atop 8 timber piles. The piers contain cross bracing to brace for pier pile sway. The piles contain minor vertical splitting but are in very good condition. There is a timber beam in between the upstream piles to support the piers from impact damage. The timber pier caps have experienced some minor horizontal splitting. The bridge piers are adequately supporting the loads from the superstructure, and there is no reason to downgrade the load rating or posting due to the condition of the piers, The load rating and load posting calculations for this structure are controlled solely by the capacity of the timber slab superstructure. The load posting analysis for this bridge results in values which do not require this bridge to be posted according to current Mn /DOT load posting guidelines. The capacity of the bridge is adequate to support the posting vehicles currently being used by Mn/DOT. Also, there are no restrictions on overweight vehicles. Report Attachments • Mn /DOT Forms RC -CL & RD -CL • Virtis Rating Results Summary Report • Bridge Inspection Notes • Annotated MnDOT Structure Inventory Report • Annotated MnDOT Bridge Inspection Report • Bridge photos taken during inspection Bridge Type 709 Rating Method ASR Roadway Width 20' -0" ❑ Curved ❑ Tapered Beam Spacing ® Live Load Distribution Factor Single See Below Multiple See Below ❑ Finite /Grid Element Analysis Bridge No. 27A34 Design Load: HS -25 Inventory Rating: HS 23.7 Operating Rating: HS 32.6 Rated AJM Checked DAN Date 6/14/2019 Sheet of 3.5" Bituminous Wearing Surface atop a 10" (Span 1 & 3) and 12" (Span 2) Thick Timber Slab Emergency3 Rating Span/ Vehicles Factor Pier Location Limit State Z Notes /Comments EV2 1.363 1 0.5 Ultimate Moment LLDF = 0.3429 EV3 0.981 1 0.6 Ultimate Moment LLDF = 0.3429 1 Elevation may be on back or another sheet if it won't fit here. 2 Choose from: service or ultimate; shear or moment 3 For information onlv 15'4" 20' -0" 15' -6" Span 1 Span 2 Span 3 BEAM ELEVATION 1 Show span lengths, structure /beam depths. Truck Rating Factor Span/ Pier Location Limit State Z Notes /Comments HS 20 Inventory 1.188 1 0.5 Ultimate Moment LLDF = 0.3 HS 20 Operating 1.632 1 0.5 Ultimate Moment LLDF = 0.3 M3 1.789 1 0.6 Ultimate Moment LLDF = 0.3429 M3S2 -40 1.789 1 0.6 Ultimate Moment LLDF = 0.3429 M3S3 -40 1.785 1 0.5 Ultimate Moment LLDF = 0.3429 SU4 1.570 1 0.5 Ultimate Moment LLDF = 0.3429 SU5 1.569 1 0.5 Ultimate Moment LLDF = 0.3429 SU6 1.558 1 0.6 Ultimate Moment LLDF = 0.3429 SU7 1.558 1 0.6 Ultimate Moment LLDF = 0.3429 Emergency3 Rating Span/ Vehicles Factor Pier Location Limit State Z Notes /Comments EV2 1.363 1 0.5 Ultimate Moment LLDF = 0.3429 EV3 0.981 1 0.6 Ultimate Moment LLDF = 0.3429 1 Elevation may be on back or another sheet if it won't fit here. 2 Choose from: service or ultimate; shear or moment 3 For information onlv FORM RD-CL BRIDGE TIN DETAILS Revised Mar. 2 017 Annual /Routine No Restriction Straddle Two Lanes 5% Impact Notes /Comments Permit Rating Factor Rating Factor Rating Factor STD. A 1.450 1.450 1.450 STD. B 1.160 1.160 1.160 STD. C 1.285 1.285 1.285 6 -axle, 90k -99k 1.656 1.656 1.656 7 -axle, 97k -99k 1.674 1.674 1.674 Special /Single No Straddle Two 5% Impact Permit Restriction Lanes Notes /Comments Rating Factor Rating Factor Rating Factor P411 1.209 1.209 ** 1.209 P413 1.160 1.160 ** 1.160 C152b 1.084 1.084 ** 1.084 C174b 1.575 1.575 ** 1.575 C214b 1.242 1.242 ** 1.242 C237b 1.328 1.328 ** 1.328 C256b 1.336 1.336 ** 1.336 C200j 1.242 1.242 ** 1.242 OVERWEIGHT PERMIT RESTRICTIONS FOR LOCAL BRIDGES Restriction Restriction Special/ Annual/ Code Description Single Routine Detailed Restriction Description Bridge Check Operation Permit Permit 1 None YES YES No Restriction to cross bridge Normal Drive on the centerline between The AASHTO "Single Lane" live two lanes, in a manner that load distribution is used. This Straddle prevents any other vehicle from operation app lies to all permit 2 Two Lanes YES YES occupying a part of either lane on vehicles when perforrrling LFR either side of the permit vehicle, method or only to annual Drive in the center of a single lane permit vehicles when bridge. performing LRFR method. Maximum YES YES The impact factor is reduced 3 speed of O O Drive at a speed of 10 mph or less from the AASHTO impact to 10 mph 5% X DENIED YES YES The overweight permit vehicle is Used when requirements for NOT ALLOWED on this bride restriction 1 thru 3 are not met Not allowed where there is a posted minimum speed. ** "N /A ", Does not apply when performing LRFR method, ref. AASHTO MBE Table 6A.4.5.4.2a -1 Q NN� t4 ,rN.+ 7 d C Rf 'IT-0 co m < N L e � CD � z Q L �C C C� G O Q. E 0 U CO U) r- o N •` N — C 0 Q m � C W N E N c N Q U) C w L N U t O N U) 2 O a) E z (n -o a a� _T l6 C Q v 0 N a N U) N O co o O N o. C 0 O c z r o mo L c m r (1)j3 o0 i l n N 6> v o 0 c c u�0� cl Eo QaH ui o.rnv_,E Uf a T ~ �<< r- O^ CL Lf to E E 7 co 0 d tm i 'IT -0 co m tl- N O m z� Q L �C C c� G O CQ C O l LJ CO Q U) O N 'C O O C N � O) (6 O Q m � C LU N ..O E O C (E Q U) C LU O N U C O O dj +' E m �L z U) m� m � m a n. N _T f6 C Q w 0 N Q N LO O co O N �? C:u,o c Z N o_ o 0 Co �i�oo N W LL o � O C (O d Q O C) E o Q�H ui oU) E N T T~ a N (0 C Q Q d L ^^O 0. (D // li. ^y� L 75 N d C c� co N � N 00 � zF- Q L �C C a) 7-> O CCL C O Wl J .Q I'' c ^^ Q v/ L N .O O — C O C 0 co � Q m U) C W N c m Q C W O 4-- N O U O C O n O a) � Q OC U C 7 m z U) m`P m� �a a� T (0 C Q 9 0 N Q N LO O N O a� c cq o 0 N O �Nrn U)4 o LL cco (1) C) J � � O < _ E ai o,N(oE N n F �<< L ^^O C W c� E E N d C ,It-0 N L N m E zF- E C(D C ^C: W O C. E O U .n QU) ti LO N •O a) — C (D c 0) m 20- m U) .a c W (D E O c m Q U) C W L O Q) _U O) C N O IL C) O U m aL+ z (n mm -00- (D T (0 C Q T O N Q N U) LO O O N N ' C O r LO O O oZrOD y cm c rn r ago° �(Nrn d' o O LL c(.0 �o� Eo aap� E U N �— N T > W (6 C Q Q Q JOB JOBNO. CALCULATED BY A DATE /I CHECKED BY PAM' DATE 6-10- M/ f"a V 1' -6 P5 t 4-oc 4- I-d- 5o le, 4f- -7 (4,q -VA Yl Val T /-F4 !> LL F16 'd << IT- 10 15"d MV- Bridge No: Date: Inspection Checklist : Superstructu e D7 A '34 County: Time In: '( D- Time Out: Bridge Type: ? Iwo Deck Type: Deck Thickness: Wear Course Type: WC Thickness: Out-Out Br Length: FF Abut to FF Abut Dist: 5o' 9 No. of Spans Span Lengths: 6. 6'/, Br. Out-Out Width: 0 Roadway Width: Curb/Rail Type: �e Beam Type: No. of Beams: Beam Spacing: Int. Bays: Ext. Bays: Beam Dimensions: Super. Condition:. I&A� C cork -T- C) L r CP�, r o0o) CA(' 0 0 e4e,� v 0t l< 001---)Y-1 Is A r Review Struot. Inv. El RevlewCond. Codes Cl Inspection Checklist e Substructure Bridge N ®: -1A 3H County: Date Time In.-, Time Out: M ,4but.'iype & Condition; �1 v� _ �a e _ `� l , �, 1 � � � � a � � � � ` ��' �' °-•ter � �� - Pier Type & Condition T`� le ._a t MINNESOTA STRUCTURE INVENTORY REPORT Bridge _.. A . i ` 1, over -- f , + G E N E R A L + Agency Br. No. District METRO Maint, Area County 27 - HENNEPIN City SHOREWOOD Township Desc. Loc. TO SHADY ISLAND Sect., Twp., Range 30 - 117N - 23W Latitude 44d 54m 43.19s Longitude 93d 38m 10.88s Custodian CITY Owner CITY f Inspection By CITY OF SHOREWOOD Year Built 1997 MN Year Remodeled FHWA Year Reconstructed Bridge Plan Location CENTRAL Potential ABC N.A. I + STRUCTURE + II Se- rvice On HIGHWAY Jervice Under STREAM Main Span Type TIMB SLAB SPAN Main Span Detail Appr. Span Type Appr. Span Detail Skew Culvert Type Barrel Length Number of Spans % MAIN: 3 APPR: 0 TOTAL: 3 ✓ Main Span Length 20.0 ft V/ Structure Length 52.0 ft I/ Deck Width 24.0 ft I/ Deck Material TIMBER J Wear Surf Type BITUMINOUS Wear Surf Install Year Wear Course /Fill Depth 0.29 ft Deck Membrane NONE Deck Rebars N/A Deck Rebars Install Year :ructure Area 1,248 sq ft Roadway Area 1,044 sq ft Sidewalk Width - L/R Curb Height - L/R Rail Codes - L/R 06 06 + ROADWAY + Bridge Match ID (TIS) 1 Roadway O/U Key 1 -ON Route Sys /Nbr MUN 81 Road Name MUN 81 National Highway System N Roadwav Function MAINLINE Roadway Type 2 WAY TRAF Control Section (TH Only) Ref. Point Date Opened to Traffic Detour Length 99 mi. Lanes 2 Lanes ON Bridge ADT (YEAR) 260 (1988) HCADT Functional Class. URBAN LOCAL + R D W Y D I M E N S I O N S + If Divided NB -EB SB - -WB Roadway Width 20.0 ft �"/ Vertical Clearance Max. Vert. Clear. Horizontal Clear. Lateral Clr. - LURt Appr. Surface Width 20.0 ft Bridge Roadway Width 20.0 It Median Width on Bridge + M I S C. B R 1 D G E D A T A + Structure Flared NO Parallel Structure NONE Field Conn. ID Cantilever ID Foundations ` Abut. TIMBER -PILE BENT �! Pier TIMBER - PILE BENT Historic Status NOT ELIGIBLE On - Off System OFF + P A I N T + Year Painted Pct. Unsound Painted Area Primer Type Finish Type + B R I D G E S I G N S + Posted Load NOT REQUIRED Traffic NOT REQUIRED Horizontal OBJECT MARKERS Vertical NOT APPLICABLE Page 1 of 4 Date: 12/20/2017 + I N S P E C T 1 O N + Deficient Status ADEQ Sufficiency Rating 74.6 Last Inspection Date 08 -29 -2017 Inspection Frequency 24 Inspector Name CITY OF SHOREWOOD Status A -OPEN + N B 1 C O N D I T I O N R A T I N G S + Deck 8 V"' Superstructure 8 Substructure 8 Channel 8 Culvert N + N B I A P P R A I S A L R A T I N G S + Structure Evaluation 8 Deck Geometry 4 Underclearances N Waterway Adequacy 9 Approach Alignment 8 + S A F E T Y F E A T U R E S + Bridge Railing 1 -MEETS STANDARDS GR Transition 0- SUBSTANDARD Appr. Guardrail 1 -MEETS STANDARDS GR Termini 0- SUBSTANDARD + I N D E P T H I N S P. + Frac. Critical N Underwater Y 60 mo 09/2016 Pinned Asbly. N I + WATERWAY + I Drainage Area Waterway Opening 200 sq It Navigation Control NO PRMT REQD Pier Protection Nay. Vert. /Horz. Clr. Nay. Vert. Lift Bridge Clear. MN Scour Code I -LOW RISK Scour Evaluation Year 2001 + C A P A C I T Y R A T I N O S + Design Load HS 25 Operating Rating HS 36.60 Inventory Rating HS 26.50 Posting Rating Date 07 -26 -2011 Overweight Permit Codes A: N B: N C: N RM—INV ORYEUB RB RT.R 12/20/2017 MINNESOTA I INSPECTION Inspected by: CITY OF SHOREWOOD BRIDGE 27A34 81(ENCHANTED LANE) OVER CHANNEL INSP. DATE: 09 -29 -2017 ,unty: HENNEPIN City: SHOREWOOD Location: TO SHADY ISLAND Route: MUN 81 Ref. Pt.: 000 +00.000 Township: Control Section: Maint. Area: Section: 30 Township: 117N Range: 23W Local Agency Bridge Nbr: Span Type: TIMB SLAB SPAN NBI Deck: 8 Super: 8 Sub: 8 Chan: 8 Culv: N Open, Posted, Closed: OPEN Appraisal Ratings - Approach: 8 Waterway: 9 MN Scour Code: ]-LOW RISK Required Bridge Signs - Load Posting: NOT REQUIRED Traffic: NOT REQUIRED Horizontal: OBJECT MARKERS Vertical: NOT APPLICABLE ELEM NBR ELEMENT NAME INSP. DATE QUANTITY 800 CRITICAL DEFS OR SAFETY HAZARDS 08 -29 -2017 1 EA 08 -20 -2015 1 EA Page 2 of 4 Length: 52.0 ft Deck Width: 24.0 ft Rdwy. Area / Pct. Unsnd: 1,044 sq ft Paint Area / Pct. Unsnd: Culvert: N/A Def. Stat: ADEQ Suff. Rate: 74.6 QTY QTY QTY QTY CS 1 CS 2 CS 3 CS 4 Notes: NO CRITICAL FINDINGS OBSERVED DURING THE LAST INSPECTION. [08/20/15] No change. [08/29/17] No change. 54 TIMBER SLAB 08 -29 -2017 1,152 SF 1,152 0 0 0 08 -20 -2015 1,248 SF 1,248 0 0 0 Notes: [2016] Migrator assumed CS1. [08/29/17] OTO width = 22' -2 ". OTO bridge field measures 52' -0 ". Slab Area = 1152 sf. Bottom of slab very clean, all spans, no indications of distress. 410 approach span, 412 main span. 510 WEARING SURFACE 08 -29 -2017 1,053 SF 1,049 4 0 0 08 -20 -2015 1,044 SF 1,044 0 0 0 Notes: (08120115] Roadway field measures 20' -3" + (2) 11 "rub rails, OTO width= 22'4 ". OTO bridge field measures 52' -07. Slab Area = 1148 sf. [08129117] Recent bituminous/gravel wear course placed across approach road and bridge - no significant depth change; good condition. (08129117] Roadway field measures 20' -3", OTO bridge 52' -0 ". Rdwy Area = 1053 sf. Typical full width transverse cracks in wear course over piers. Say (2 piers) * (20.25) * (1 %12 crack width) => say 4 SF at CS -2, balance at CS -1. 332 TIMBER BRIDGE RAILING 08 -29 -2017 104 LF 104 0 0 0 08 -20 -2015 104 LF 104 0 0 0 Notes: [08/20/15] No change. [08/29/17] No change. 822 BITUMINOUS APPROACH ROADWAY 08 -29 -2017 2 EA 2 0 0 0 08 -20 -2015 2 EA 2 0 0 0 Notes: [08/20/15] No change. [08/29/17] Recent bituminous /gravel wear course placed across approach road; good condition. 216 TIMBER ABUTMENT 08 -29 -2017 92 LF 92 0 0 0 08 -20 -2015 102 LF 102 0 0 0 Notes: [2016] Migrator added 40 LF to abutment quantity to account for wingwalls (CS1:40 CS2:0 CS3:0 CS4:0). [08/20/15] Slight quantity change for field measured dimensions, no condition state change. Wingwall notes: [08/20/15] No change. [08/29/17] Field measure 2' OH (N) + (2) 8' WW + 6' OH (S) + 22' OTO = 46 LF * 2 = 92 LF; all CS -1 228 TIMBER PILING 08 -29 -2017 36 EA 36 0 0 0 08 -20 -2015 36 EA 36 0 0 0 Notes: [08/20/15] Remove timber column quantity, coded incorrectly. 10 piles at each abutment/ww + 8 piles at each pier, total = 36, all in Condition State 1. [08/29/17] Steel shims under the timber cap of a few piles; all piles in contact with cap or shims; no CS change. z35 TIMBER PIER CAP 08 -29 -2017 120 LF 120 0 0 0 08 -20 -2015 124 LF 124 0 0 0 Notes: [08/20/15] Slight quantity change for field measured dimensions, no condition state change. [08/29/17] 4 @ 30' -2" = 120 LF; all CS -1. Minor weathering on the exposed overhangs. Page 3 of 4 855 SECONDARY MEMBERS (SUPER) 08 -29 -2017 1 EA 1 o n n Notes: [08/29/17] Member added for spreader beams. Deleted Floorbeam (Item 156). Member is secondary, acts as a diaphragm, not a primary member which a floor beam is, disagree with BSIPM B.3.3.4. Notes below from previous inspection. Item is a "1" qty, all spreader beams in good condition, CS -1. [08/20/15] Element added. 12x6 timber section; (1) stiffener beam in each approach span & (2) stiffener beams in the main span. Same quantity as timber cap, 124 LF, all in Condition State 1 885 SCOUR 08 -29 -2017 1 EA 1 0 0 0 08 -20 -2015 1 EA 1 0 0 0 Notes: [08/29/17] No scour evident, channel armor in place. Underwater inspection performed 09/07/16. 891 OTHER BRIDGE SIGNING 08 -29 -2017 1 EA 08 -20 -2015 1 EA Notes: [08/29/17] Member added for timber curb, part of the timber rail system. Good condition throughout; CS -1. 899 MISCELLANEOUS ITEMS 08 -29 -2017 1 EA 08 -20 -2015 1 EA Notes: [08/20/15] Element added. (3) separate conduits on the south side of the bridge. (1) 3" gas line, marked at east end of le bridge; (1) 16" conduit (insulated water main ?); & (1) 4" conduit (galvanized ?). [08/29/17] Gas marker on east end of bridge, totally obscured by vegetation; no marker visible on the west end; downgrade to CS -3 for vegetation removal around this and object marker sign. 900 PROTECTED SPECIES 08 -29 -2017 1 EA 08 -20 -2015 1 EA Jd Notes: Use this element to track the presence of protected species living on this structure. [08/29/17] Swallow nests on bridge, CS -2. General [08/20/15] Inspection by WSB. Notes: [08/20/15] 40" clearance to bottom of spreader beam in Span 2. [08/20/15] 4' water depth in channel under Span 2. [08/20/15] Removed element 206. [08/20/15] Added element 228. [08/20/15] Added element 415. [08/20/15] Added element 981. [08/20/15] Vegetation growing at SW corner of bridge, nearly obstructing object markers, should be removed. [08/29/17] Inspection by WSB & Associates. Vegetation growing at SW & SE corner of bridge, nearly obstructing object markers, should be removed. [08/29/17] 2011 load rating does not include SHV load ratings. See BSIPM A.8.2: "Section 15.6 of the MnDOT LRFD Bridge Design Manual states that a new bridge load rating should be calculated whenever change occurs that would sufficiently change the rating. The most commonly encountered types of changes are: A change in the laws regulating truck weights." Owner should consider load rating bridge with updated SHV truck loads. Deck: [8] [08/20/15] Timber slab covered by 3.5" bituminous wear course; no change. Measures 2" at the gutter line, 5" at CL bridge. [08/29/17] Recent bituminous /gravel wear course placed across approach road and bridge - no significant depth change. Notes: [08/20/15] Element added. All object markers accounted for and visible. Vegetation growth at SW corner of abutment growing up around object marker. [08/29/17] Heavy vegetation at SW and SE corners, beginning to obscure signs. [08/29/17] Gas marker on east end of bridge, totally obscured by vegetation; no marker visible on the west end; downgrade to CS -3 for vegetation removal around object marker sign. 892 SLOPES & SLOPE PROTECTION 08 -29 -2017 1 EA 1 0 0 0 08 -20 -2015 1 EA 1 0 0 0 Notes: [08/20/15] No change, channel slopes well protected. [08/29/17] No change. 893 GUARDRAIL 08 -29 -2017 1 EA 1 0 0 0 08 -20 -2015 1 EA 1 0 0 0 Notes: [08/20/15] No change. [08/29/17] No change. 894 DECK & APPROACH DRAINAGE 08 -29 -2017 1 EA 1 0 0 0 08 -20 -2015 1 EA 1 0 0 0 Notes: [08/20/15] No change, deck scuppers open, free of debris. [08/29/17] No change. 895 SIDEWALK, CURB, & MEDIAN 08 -29 -2017 1 EA 1 0 0 0 Notes: [08/29/17] Member added for timber curb, part of the timber rail system. Good condition throughout; CS -1. 899 MISCELLANEOUS ITEMS 08 -29 -2017 1 EA 08 -20 -2015 1 EA Notes: [08/20/15] Element added. (3) separate conduits on the south side of the bridge. (1) 3" gas line, marked at east end of le bridge; (1) 16" conduit (insulated water main ?); & (1) 4" conduit (galvanized ?). [08/29/17] Gas marker on east end of bridge, totally obscured by vegetation; no marker visible on the west end; downgrade to CS -3 for vegetation removal around this and object marker sign. 900 PROTECTED SPECIES 08 -29 -2017 1 EA 08 -20 -2015 1 EA Jd Notes: Use this element to track the presence of protected species living on this structure. [08/29/17] Swallow nests on bridge, CS -2. General [08/20/15] Inspection by WSB. Notes: [08/20/15] 40" clearance to bottom of spreader beam in Span 2. [08/20/15] 4' water depth in channel under Span 2. [08/20/15] Removed element 206. [08/20/15] Added element 228. [08/20/15] Added element 415. [08/20/15] Added element 981. [08/20/15] Vegetation growing at SW corner of bridge, nearly obstructing object markers, should be removed. [08/29/17] Inspection by WSB & Associates. Vegetation growing at SW & SE corner of bridge, nearly obstructing object markers, should be removed. [08/29/17] 2011 load rating does not include SHV load ratings. See BSIPM A.8.2: "Section 15.6 of the MnDOT LRFD Bridge Design Manual states that a new bridge load rating should be calculated whenever change occurs that would sufficiently change the rating. The most commonly encountered types of changes are: A change in the laws regulating truck weights." Owner should consider load rating bridge with updated SHV truck loads. Deck: [8] [08/20/15] Timber slab covered by 3.5" bituminous wear course; no change. Measures 2" at the gutter line, 5" at CL bridge. [08/29/17] Recent bituminous /gravel wear course placed across approach road and bridge - no significant depth change. Brdg [1] [08/20/15] Change to substandard. Railings: [08/29/15] Barrier is standard for — 40 mph. Transitions: [0] [08/20/15] No change. [08/29/15] Change to substandard. Appr [1] [08/20/15] No change. Guardraill: [08/29/15] No change. Appr Guardrail [0] [08/20/15] Change to substandard. Approach guardrail ends are turned down. Terminal : [08/29/15] No change. Superstructure: [8] [08/20/15] Timber slab covered by 3.5" bituminous wear course; bottom of timber slab stringers in very good condition in all spans, no change. [08/29/17] 4x10 approach span, 4x12 main span. Substructure: [8] [08/20/15] No change. [08/29/17] No change. Channel: [8] [08/20/15] No change. 40" freeboard to Span 2 spreader beam. [08/29/17] Downgrade to 8, bridge no longer in 'new' condition. Culvert: [N] [08/20/15] No change. [08/29/17] No change. Waterway [9] [08/20/15] No change. Adeq: [08/29/17] No indications of high -water anywhere near low bridge member. Appr Roadway [8] [08/20/15] No change. Alignment: [08/29/17] No change. 44"_ Page 4 of 4